Date: 06/17/2023
problemWalk in cooler Install New Evaporator Coils
diagnosticsWalk in Cooler Repair Installation
repairWalk in Cooler Installation New Evaporator Coils
locationLos Angeles
Date: 05/17/2023
problemDoor frame Heater Not Working
diagnosticsDoo Frame Heater is Broken
repairReplaced Door frame Heater
locationLos Angeles
Date: 03/17/2023
problemWalk In Freezer Not Keep Negative Temperature
diagnosticsWalk in Freezer Compressor Out Off Service
repairReplaced Walk in Freezer Compressor
locationLos Angeles
Date: 03/01/2023
problemNot working
diagnosticsLow refrigerant in refrigeration system
repairpreformed pressure test fid and repair leaking refrigerant ,charge refrigerant
locationPasadena
Date: 01/17/2023
problemDoor Window Collect moister
diagnosticsBroken Seal around windows frame
repairReplaced seal
locationLos Angeles
Date: 04/13/2022
problemCommercial Blodgett Oven is not getting hot, not working.
diagnosticsInspected Combination Blodgett Oven and found: Boiler unit is not operating properly.
repairRecommended to replace the boiler unit.
locationWest Hollywood
Date: 04/13/2022
problemCommercial Deep Fryer is not getting hot.
diagnosticsInspected Deep Fryer and found: Thermocouple is broken, not working.
repairRecommended to replace the thermocouple unit.
locationWestlake Village
Date: 04/12/2022
problemCommercial Blodgett Oven is not igniting.
diagnosticsInspected Blodgett Oven and found: Spark ignition module is not working properly.
repairRecommended to replace the spark ignition module.
locationLa Verne
Date: 04/12/2022
problemWalk-In Cooler is not keeping temperature.
diagnosticsInspected Walk-In Refrigerator and found: Door of the refrigerator is broken.
repairRecommended to replace the Cooler door.
locationThousand Oaks
Date: 04/11/2022
problemWalk-In Refrigerator is leaking.
diagnosticsInspected Commercial Walk-In Refrigerator and found: Drain line is clogged.
repairRecommended to perform drain line service.
locationManhattan Beach
Date: 04/11/2022
problemAir Conditioning unit is not blowing cold air.
diagnosticsInspected the Air Conditioning Unit and found: Refrigerant is low.
repairRecommended to recharge refrigerant.
locationChatsworth
Date: 03/12/2022
problemCommercial Walk In Cooler is leaking water.
diagnosticsInspected Walk In Refrigerator and found: Drain line is clogged, not going through.
repairRecommended to service and clean out the drain line.
locationLos Angeles
Date: 03/10/2022
problemCommercial Display Case is not cold, too warm.
diagnosticsInspected Display Case and found: Fan motor is not running.
repairRecommended to replace the condenser fan motor.
locationWestlake Village
Date: 03/04/2022
problemCommercial Walk-In Freezer is not cold, too warm.
diagnosticsInspected Walk In Freezer and found: Condenser and evaporator coils are very old.
repairRecommended to install 2 new condenser and evaporator coils.
locationLos Angeles
Date: 03/01/2022
problemCommercial Pizza Oven is not heating, cold.
diagnosticsInspected Commercial Pizza Oven and found: Thermostat is not working, broken.
repairRecommended to replace the thermostat.
locationCulver City
Date: 02/28/2022
problemCommercial Grill is not igniting on 2 burners.
diagnosticsInspected Commercial Grill and found: Module is broken.
repairRecommended to replace the heating module.
locationLos Angeles
Date: 02/16/2022
problemCommercial Dishwasher is not draining.
diagnosticsInspected Dishwasher and found: Drain valve is clogged/broken.
repairRecommended to replace the drain valve.
locationSanta Monica
Date: 02/14/2022
problemCommercial Scottsman Ice Machine is not making ice.
diagnosticsInspected Scottsman Ice Machine and found: Machine is dirty, not sanitized.
repairRecommended to deep clean and sanitize, also replace the water filter.
locationThousand Oaks
Date: 02/09/2022
problemCommercial Walk In Cooler is not cold, too warm.
diagnosticsInspected Walk-In Cooler and found: Compressor is not working anymore.
repairRecommended to replace the compressor.
locationSylmar
Date: 02/08/2022
problemCommercial Steam Table is not heating up, not warm.
diagnosticsInspected Steam Table and found: Thermostats are not functioning properly.
repairRecommended to replace the 2 thermostats and the control light.
locationSan Fernando Valley
Date: 02/02/2022
problemCommercial Walk-In Freezer is overfreezing, too cold.
diagnosticsInspected Walk-In Freezer and found: Defrost timer is not working properly. Compressor parts are worn out.
repairRecommended to replace the defrost time and compressor components.
locationPasadena
Date: 01/24/2022
problemCommercial Walk-In Cooler is not keeping temperature.
diagnosticsInspected the Walk In Refrigerator and found: Curtains at the door are falling apart. Thermostat is not working.
repairRecommended to replace the curtains and replace thermostat.
locationWoodland Hills
Date: 01/20/2022
problemCommercial Double Convection Oven is not heating up enough, only warm.
diagnosticsInspected Commercial Convection Oven and found: Calibration is off.
repairRecommended to recalibrate the unit.
locationLos Angeles
Date: 01/20/2022
problemCommercial Ice Machine is dirty and needs maintenance.
diagnosticsInspected Commercial Ice Maker and found: Condenser and other parts are dirty.
repairRecommended to do a full sanitizing and cleaning on the unit, every 6 months.
locationChatsworth
Date: 01/10/2022
problemSoda Machine is no longer cold.
diagnosticsInspected the Soda Machine Refrigerator and found: Condenser fan motor is not operating and compressor is broken.
repairRecommended to replace the condenser fan motor and compressor.
locationMoorpark
Date: 01/05/2022
problemWalk-In Freezer is not working properly, too warm.
diagnosticsInspected the condenser and found fan motor is not spinning. Low refrigerant.
repairRecommended to replace the condenser fan motor and recharge refrigerant.
locationLos Angeles
Date: 12/16/2021
problemPrep table is not cold, warm.
diagnosticsPrep table has a low level of refrigerant.
repairRecommended to recharge refrigerant.
locationLos Angeles
Date: 08/17/2021
problemDisplay Case is not cold, warm.
diagnosticsDisplay Case Refrigerator refrigerant is low.
repairRecommended to recharge refrigerant.
locationWest Hollywood
Date: 08/06/2021
problemCommercial Walk-In Refrigerator needs new condensing units.
diagnosticsNew installation of condensing units is required on the roof due to warm Walk-In Refrigerator.
repairInstallation completed with new condensing units.
locationLos Angeles
Date: 08/06/2021
problemOven is not heating, not turning on.
diagnosticsInspected Commercial Oven and found: Thermostat is out of order.
repairRecommended to replace the thermostat.
locationAgoura Hills
Date: 08/06/2021
problemCommercial Freezer is not cold, too warm.
diagnosticsInspected Commercial Freezer and found: Compressor is out of order.
repairRecommended to replace the compressor.
locationTorrance
Date: 08/06/2021
problemWalk-In Cooler is too warm.
diagnosticsCommercial Walk-In Cooler needs new evaporator coils.
repairInstallation completed with new evaporator coils.
locationLos Angeles
Date: 08/06/2021
problemCommercial Vulcan Stove does not have any gas coming out.
diagnosticsInspected the Vulcan Stove and found: Gas valve coils are not working.
repairRecommended to replace the gas valve coils.
locationOxnard
Date: 08/06/2021
problemCommercial Wolf Stove is not igniting properly.
diagnosticsInspected Wolf Stove and found: infrared element is not working properly.
repairRecommended to replace the grill infrared element.
locationBeverly Hills
Date: 07/16/2021
problemCommercial Walk In Freezer has an iced up door window.
diagnosticsInspected Walk-In Freezer and found: Door frame and window heater is not working properly, out of order.
repairRecommended to replace the door frame and window heater.
locationBeverly Hills
Date: 07/16/2021
problemCommercial Oven is not lighting up inside.
diagnosticsInspected the Commercial Oven and found: Light bulb assembly is not working properly.
repairRecommended to replace the light bulb sucker assembly.
locationLos Angeles
Date: 07/16/2021
problemCommercial Walk In Cooler needs to be replaced.
diagnosticsInstallation of a new Walk-In Cooler.
repairInstallation of a new condenser and evaporator coils.
locationGlendora
Date: 07/16/2021
problemHoshizaki Ice Machine is not making enough ice.
diagnosticsInspected Commercial Hoshizaki Ice Machine and found: Gear motor is not working properly.
repairRecommended to replace the gear motor and sanitize the ice machine.
locationWest Hollywood
Date: 07/16/2021
problemCommercial Walk In Freezer needs new curtains.
diagnosticsInspected Commercial Walk-In Freezer and: Took measurements and ordered new curtains.
repairInstalled new freezer curtains.
locationWest Hollywood
Date: 07/16/2021
problemMobile Freezer is not cooling properly.
diagnosticsInspected Mobile Freezer and found: Condenser coils are blocked and refrigerant is leaking out.
repairRecommended to repair the evaporator coils and fix the refrigerant leak, along with recharging refrigerant.
locationLos Angeles
Date: 07/16/2021
problemCommercial A/C is not as cold as before.
diagnosticsCommercial A/C needs to be serviced.
repairRecommended to perform semi-annual maintenance and service.
locationLos Angeles
Date: 07/16/2021
problemWalk-In Cooler is not too warm.
diagnosticsInspected Commercial Walk In Cooler and found: Compressor is not functioning properly, control board is malfunctioning.
repairRecommended to replace the compressor and control board.
locationLos Angeles
Date: 07/16/2021
problemCommercial Walk In Cooler is not cooling enough, too warm.
diagnosticsInspected Walk-In Cooler and found: Evaporator coils are not conducting properly.
repairRecommended to replace the existing evaporator coil assembly.
locationCamarillo
Date: 07/16/2021
problemCommercial Swamp Cooler is not turning on.
diagnosticsInspected Swamp Cooler and found: Cooler assembly is out of order.
repairRecommended to replace the swamp cooler assembly.
locationLos Angeles
Date: 07/15/2021
problemCommercial Refrigerator is not cooling, too warm.
diagnosticsInspected Commercial Refrigerator and found: Cold control is not working properly, out of order.
repairRecommended to replace the cold control and evaporator coils cover.
locationLos Angeles
Date: 07/15/2021
problemCommercial freezer is icing up.
diagnosticsInspected commercial freezer and found: Defrost system is out of order.
repairRecommended to reprogram and reset the defrost system.
locationManhattan Beach
Date: 07/15/2021
problemCommercial Walk-In Cooler has a broken light, not lighting.
diagnosticsInspected Walk In Cooler and found: Light switch is broken.
repairRecommended to replace the light switch.
locationLos Angeles
Date: 07/15/2021
problemCommercial Walk-In Cooler is not cold, too warm.
diagnosticsInspected the walk in cooler and found: Compressor is not working properly, out of order.
repairRecommended to replace the compressor.
locationWest Hollywood
Date: 07/15/2021
problemCommercial Walk In Freezer is not cold, too warm.
diagnosticsInspected Walk In Freezer and found: Evaporator fan is not spinning properly, out of order.
repairRecommended to replace the evaporator fan motor.
locationThousand Oaks
Date: 07/02/2021
problemCommercial Ice Machine is not producing ice,not working.
diagnosticsInspected Commercial Ice Machine and found: Check valve is blocked.
repairRecommended to replace the check valve.
locationWest Hollywood
Date: 07/02/2021
problemCommercial Freezer is not cold, warm.
diagnosticsInspected Commercial Freezer and found: Evaporator coils are out of order.
repairRecommended to replace the evaporator coils.
locationWest Hollywood
Date: 07/02/2021
problemCommercial Walk-In Freezer is not cold enough, warm.
diagnosticsInspected Walk In Freezer and found: Evaporator fan is not functioning, broken.
repairRecommended to replace the evaporator fan motor.
locationLos Angeles
Date: 07/02/2021
problemCommercial Walk-In Cooler is not cold, warm.
diagnosticsInspected Walk-In Refrigerator and found: Thermostat is broken, not working.
repairRecommended to replace the thermostat.
locationSherman Oaks
Date: 07/02/2021
problemCommercial Walk-In Cooler is not cooling properly, warm.
diagnosticsInspected Walk In Cooler and found: Thermostat and light switch is out of order, broken.
repairRecommended to replace the light switch and thermostat.
locationSanta Fe Springs
Date: 07/02/2021
problemCommercial Deep Fryer is not heating.
diagnosticsInspected Deep Fryer and found: Pilot light is not igniting, generator is broken.
repairRecommended to replace the pilot generator.
locationLos Angeles
Date: 06/18/2021
problemCommercial Walk In Freezer has a build up of ice.
diagnosticsInspected Walk-In Freezer and found: Defrost timer is not working, out of order.
repairRecommended to replace the defrost timer.
locationLos Angeles
Date: 06/18/2021
problemCommercial Walk-In Freezer is not cooling, too warm.
diagnosticsInspected Walk In Freezer and found: Compressor fan motor is out of order, not working.
repairRecommended to replace the compressor fan motor.
locationBurbank
Date: 06/18/2021
problemA/C is not blowing cold air.
diagnosticsInspected Air Conditioning unit and found: Refrigerant level is low.
repairRecommended to recharge the refrigerant.
locationVenice
Date: 06/18/2021
problemCommercial Steamer is not heating up, not steaming.
diagnosticsInspected Commercial Steamer and found: Water control board is out of order, broken.
repairRecommended to replace the water control board.
locationLos Angeles
Date: 06/18/2021
problemCommercial oven is not heating.
diagnosticsInspected oven and found: Glow igniter is broken and light bulb is out.
repairRecommended to replace the glow igniter and light bulb assembly.
locationLos Angeles
Date: 05/22/2021
problemCommercial Beer Cooler is not cold, warm.
diagnosticsInspected commercial beer chiller and found: Compressor is not working, out of order.
repairRecommended to replace the compressor.
locationVan Nuys
Date: 05/22/2021
problemCommercial salad prep table is not cold, warm.
diagnosticsInspected salad bar and found: Evaporator coils are damaged, no longer working.
repairRecommended to replace the evaporator coils.
locationLos Angeles
Date: 05/22/2021
problemCommercial hood is no longer working.
diagnosticsInspected the commercial hood and found: Belt drive is broken.
repairRecommended to replace the belt drive.
locationSimi Valley
Date: 05/22/2021
problemCommercial refrigerator is not cold, warm.
diagnosticsInspected commercial refrigerator and found: Evaporator fan is not spinning, out of order.
repairRecommended to replace the evaporator fan motor.
locationCamarillo
Date: 05/22/2021
problemCommercial ice machine is not making ice, broken.
diagnosticsInspected ice machine and found: Filter is clogged.
repairRecommended to replace the water filter.
locationLos Angeles
Date: 05/22/2021
problemCommercial Walk-In Cooler is leaking.
diagnosticsInspected walk in cooler and found: Leaking refrigerant, has a leak in the system.
repairRecommended to repair the leak and recharge refrigerant.
locationVenice
Date: 05/22/2021
problemCommercial oven is not working, not turning on.
diagnosticsInspected oven and found: Hood motor is out of order.
repairRecommended to replace the hood motor.
locationLos Angeles
Date: 05/22/2021
problemCommercial Air Conditioning is not working, out of order.
diagnosticsInspected commercial A/C and found: Main board is not working properly, broken.
repairRecommended to replace the main control board.
locationPacific Palisades
Date: 05/22/2021
problemCommercial Walk-In Cooler is not cold, warm.
diagnosticsInspected walk in cooler and found: Compressor is not working, broken.
repairRecommended to replace the compressor.
locationTarzana
Date: 05/22/2021
problemCommercial Walk-In Freezer has a broken door.
diagnosticsInspected walk in freezer and found: Door is old, not opening properly.
repairRecommended to replace the freezer door.
locationLos Angeles
Date: 05/22/2021
problemCommercial Walk-In Cooler is not cold, warm.
diagnosticsInspected commercial Walk In Cooler and found: Compressor is broken.
repairRecommended to replace the compressor.
locationCalabasas
Date: 05/22/2021
problemCommercial oven is not turning on, not heating.
diagnosticsInspected commercial oven and found: Thermostat is out of order, broken.
repairRecommended to replace the thermostat.
locationPasadena
Date: 05/20/2021
problemPizza Oven is not working, not igniting.
diagnosticsInspected commercial pizza oven and found: Temperature sensor is out of order, not working.
repairRecommended to replace the temperature sensor.
locationLos Angeles
Date: 05/20/2021
problemCommercial freezer is not cold.
diagnosticsInspected freezer and found: Defrost timer is not working, out of order.
repairRecommended to replace the defrost timer.
locationChatsworth
Date: 05/16/2021
problemCommercial Refrigerator is leaking water.
diagnosticsInspected refrigerator and found: Drain line is clogged.
repairRecommended to perform drain line cleaning service.
locationSun Valley
Date: 05/13/2021
problemCommercial Walk-In Cooler has a leak.
diagnosticsInspected Commercial Walk In Cooler and found: Leak is present on the evaporator coils, refrigerant level is low.
repairRecommended to repair the leak on the coils and recharge refrigerant.
locationLos Angeles
Date: 05/13/2021
problemCommercial oven is not broiling.
diagnosticsInspected Commercial Oven and found: Broiler element is out of order, not working.
repairRecommended to replace the broiler element.
locationLos Angeles
Date: 05/12/2021
problemCommercial Ice machine is not producing ice.
diagnosticsInspected ice machine and found: Harvest relay is not working properly.
repairRecommended to replace the harvest relay.
locationLos Angeles
Date: 05/08/2021
problemHoshizaki Ice Machine is leaking water.
diagnosticsInspected ice machine and found: Evaporator spring is loose.
repairRecommended to replace the evaporator spring to stop leak.
locationLos Angeles
Date: 05/08/2021
problemCommercial Freezer is not cold enough, too warm.
diagnosticsInspected Commercial Freezer and found: Refrigerant levels are low.
repairRecommended to distribute a stop leak chemical and recharge refrigerant.
locationChatsworth
Date: 05/08/2021
problemConvection Oven is not heating.
diagnosticsInspected commercial convection oven and found: Ignition module is not working correctly.
repairRecommended to replace the ignition module.
locationLos Angeles
Date: 05/08/2021
problemOld Swamp Cooler / Evaporative Cooler was broken and old, needed replacement.
repairInstalled a new Swamp Cooler / Evaporative Cooler.
locationToluca Lake
Date: 05/08/2021
problemCommercial oven is not igniting, not heating.
diagnosticsInspected commercial oven and found: Flame sensor is not operating correctly.
repairRecommended to replace the flame sensor.
locationStudio City
Date: 05/07/2021
problemRefrigerator is warm, not as cold as it should be.
diagnosticsInspected commercial refrigerator and found: Condenser is not working properly.
repairRecommended to perform condenser service.
locationSherman Oaks
Date: 05/7/2021
problemCommercial salad bar refrigerator is not cold, warm.
diagnosticsInspected the salad bar refrigerator and found: Refrigerant level is low, possible leak.
repairRecommended to distribute stop leak chemical and recharge refrigerant.
locationThousand Oaks
Date: 04/29/2021
problemPrep table is not cooling.
diagnosticsInspected Prep Table and found: Condenser fan motor is not working, out of order.
repairRecommended to replace the condenser fan motor.
locationSylmar
Date: 04/29/2021
problemDefrost cycle is not coming on, broken.
diagnosticsInspected Commercial Walk In Freezer and found: Evaporator fan and defrost control is out of order, not working.
repairRecommended to replace the defrost control and fan motor control.
locationCalabasas
Date: 04/29/2021
problemDoor hinges are not working properly.
diagnosticsInspected Commercial Refrigerator and found: Door hinges are worn.
repairRecommended to replace door hinges.
locationSanta Monica
Date: 04/27/2021
problemOven is not working, no heat or power.
diagnosticsInspected Imperial Oven and found: Thermostat is out of order, broken.
repairRecommended to replace the oven thermostat.
locationLos Angeles
Date: 04/27/2021
problemNot making ice.
diagnosticsInspected ice machine and found: Issues with the compressor and running capacitor.
repairRecommended to replace the compressor running capacitor.
locationLos Angeles
Date: 04/27/2021
problemDoors on the unit are not closing properly, not sealed.
diagnosticsInspected refrigerator and found: Door hinges are worn, not working.
repairRecommended to replace the door hinges.
locationLos Angeles
Date: 04/23/2021
problemSalad Bar is not cold, warm.
diagnosticsInspected Salad Bar refrigerator and found: Low level pressure of refrigerant.
repairRecommended to repair the leak and recharge refrigerant.
locationSanta Monica
Date: 04/23/2021
problemCommercial refrigerator is not getting cold, warm.
diagnosticsInspected refrigerator and found: Compressor is out of order, broken.
repairRecommended to replace the compressor and recharge refrigerant.
locationSherman Oaks
Date: 04/16/2021
problemDefrost is not working, forming ice.
diagnosticsInspected commercial Walk In Cooler and found: Defrost timer is out of order, not working.
repairRecommended to replace the defrost timer.
locationAgoura Hills
Date: 04/16/2021
problemMachine is not making ice.
diagnosticsInspected the Commercial Ice Machine and found: Circulation pump is not working properly, out of order.
repairRecommended to replace the Circulation Pump.
locationCalabasas
Date: 04/14/2021
problemNot working properly, too warm.
diagnosticsInspected deep freezer and found: Low pressure of refrigerant.
repairRecommended to patch / repair the leak and recharge the refrigerant.
locationWestlake Village
Date: 04/14/2021
problemNot cold enough, too warm.
diagnosticsInspected Walk In Cooler and found: Low pressure of refrigerant.
repairRecommended to patch / repair the leak and charge refrigerant.
locationWestlake Village
Date: 04/12/2021
problemDoors are not opening properly.
diagnosticsInspected Commercial Refrigerator and found: Door hinges are old, worn.
repairRecommended to replace door hinges and door springs.
locationLos Angeles
Date: 04/12/2021
problemConditioning unit is not working, blowing warm air.
diagnosticsInspected Aero Conditioner Unit and found: Compressor is out of order, not working.
repairRecommended to replace Condenser Unit.
locationLos Angeles
Date: 04/12/2021
problemUnit is leaking water.
diagnosticsInspected Walk In Freezer and found: Defrost cycle is not working properly.
repairRecommended to replace the defrost terminator, adjust thermostat, and adjust defrost timer.
locationLos Angeles
Date: 04/01/2021
problemNot cooling properly.
repairRecommended to perform condenser coil service and deep cleaning.
locationLos Angeles
Date: 04/01/2021
problemNot cold, warm
diagnosticsInspected Turbo Air refrigerator and found: low pressure refrigerant, condenser is blocked.
repairRecommended to recharge refrigerant, distribute stop leak chemical, and perform condenser service.
locationLos Angeles
Date: 04/01/2021
problemNot making ice / no ice dispensing.
diagnosticsInspected Commercial Ice Machine and found: motor was pushed out of order, condenser is blocked, and broken Harvest Motor Assembly.
repairNeed to replace Harvest Motor Assembly and perform condenser coils service.
locationLos Angeles
Date: 03/29/2021
problemiced up ,leaking water
diagnosticsInspected Walk in Freezer , found :Drain line heater not working ,drain line is frozen ,on defrost cycle drain pan overflow and leaking in side Walk in freezer on flor
repairRecommend defrost drain pan ,drain line and replace 230 volt drain heater and drain line insulation
locationLos Angeles
Date: 03/29/2021
problemIce Machine not making ice
diagnosticsInspected Ice Machine, found Low Water flow pressure from Water supply to the ice Machine , Water Filter is blocked .
repairRecommended to replace Water Filters
locationThousand Oaks
Date: 03/29/2021
problemWalk in Cooler not cooling
diagnosticsAfter inspection , found : Internal Leaking Refrigerant on Evaporator Coils
repairRecommend Recovery Refrigerant ,Remove and Replaced Evaporator Coils ,Pressure test for leaking Vacuum Sealed System , Charge Refrigerant
locationSanta Monica
Date: 12/29/2019
problemNo heat
diagnosticsAfter diagnoses ,found :spark ignition control module out of order
repairReplaced ignition control module
locationLos Angeles
Date: 12/26/2019
problemDoor won,t closed properly
diagnosticsNeed replace door closer hinge & door gasket
repairReplaced door closer hinge and Door gasket
locationTarzana
Date: 12/20/2019
problemOven leaking water
diagnosticsConvection Blodgett oven Boiler is leaking ,
repairReplaced existing boiler
locationLos Angeles
Date: 12/18/2019
problemLeaking
diagnosticsAfter diagnoses ,found drain line is need service
repairCleaning drain line ,no more leak
locationLos Angeles
Date: 12/10/2019
problemError code temp sensor
diagnosticsreset control board
repairreset control board
locationLos Angeles
Date: 12/10/2019
problemOven does not ignite
diagnosticsAfter diagnostics found ,blower inDuser fan motor stock did start
repairReplaced inDuser blower motor, check oven ,works Okay
locationThousand Oaks
Date: 12/09/2019
problemDoor not closed by it self
diagnosticsDoor spring and hinge is broken
repairReplaced door spring and hinge
locationSimi Valley
Date: 12/02/2019
problemnot cold
diagnosticscompressor does not work
repairrecovery freon,removal old compressor, filter dryer, overload relay start /run capacitors. install new compressor,filter dryer,overload relay start run capacitor preform pressure test ,for leaking freon charge refrigerant R 404 A,start freezer.Works Okay.
locationLos Angeles
Date: 10/09/2019
problemNot making ice
diagnosticsCompressor hot wire burned out ,of over heating ,condenser need service
repairreplaced wire on compressor ,preform condenser deep cleaning ,adjust evaporator ice cubs size
locationPasadena
Date: 09/09/2019
problemOven not turning on ,pilot lights not starting lit
diagnosticsOven ignition control and spark igniter,fault
repairopen front panel, remove burners out ,replaced ignition control and pilot with spark igniter
locationSan bernardino
Date: 09/02/2019
problemRefrigerator is not keeping 40 F temperature.
diagnosticsUnit has been disassembled. After diagnostics we found that an evaporator fan motor is broken.
repairUsing available parts a repair is completed by replacing evaporator fan motor. Perform a diagnostic after a repair is done to make sure a unit is reaching a required temperature.
locationBeverly Hills
Date: 08/19/2019
problemRefrigerator make loud nosy
diagnosticsAfter diagnoses ,condenser fan motor is broken .
repairreplaced condenser fan motor ,preform condenser service
locationLos Angeles
Date: 08/18/2019
problemWalk in cooler not working
diagnosticsEvaporator fan motor out of order
repairReplaced evaporator fan motor
locationSan bernardino
Date: 08/13/2019
problemIce Machine does not make ice
diagnosticsAfter diagnoses , found water flow valve is broken
repairreplaced water flow valve,preform condenser service ,replaced water filter
locationChatsworth
Date: 07/05/2019
problemIce cream machine not make ice cream
diagnosticsChecked up unit ,found ;power supply board out of order
repairReplaced power supply board
locationSherman oaks
Date: 05/29/2019
problemLeaking water
diagnosticsAfter inspection ,found drain line is blocked
repairNeed Service and cleaning drain line
locationSan Bernardino
Date: 05/28/2019
problemNot cold
diagnosticsAfter diagnoses , found :Condenser coils is blocked , low pressure freon
repairpreformed condenser service,charge freon
locationVenice
Date: 05/28/2019
problemPilot Wont stay on
diagnosticsafter diagnoses ,found Thermocouple burned out .
repairReplaced exciting thermocouple
locationSanta Monica
Date: 05/28/2019
problemNo heating
diagnosticsAfter diagnoses ,found oven thermostat out of order
repairReplaced oven thermostat
locationBeverly Hills
Date: 03/23/2019
problemFlower cooler leaking water
diagnosticsDrain line is blocked
repairPreform drain line service
locationLos Angeles
Date: 03/12/2019
problemCommercial true refrigerator beer cooler not cold
diagnosticsDiagnoses condenser fan motor stop working ,compressor overheated and burned out
repairReplaced condenser fan motor install new compressor, filter dyer , charge freon r 134 a
locationSan bernardino
Date: 03/12/2019
problemNot working
diagnosticsDiagnoses main control board out off order, prob error
repairReplace Main control board and prob
locationSan Bernardino
Date: 03/08/2019
problemUpper oven no ignite
diagnosticsAfter inspection , found :spark ignition control module ,out of order, need replace control ignition module
repairReplaced existing spark ignition control module
locationLos Angeles
Date: 03/07/2019
problemLeaking Water from Evaporator coils
diagnosticsEvaporator drip pan rust true & leaking Water
repairReplaced existing Evaporator coils
locationLos Angeles
Date: 03/01/2019
problemError code Boiler limit open
diagnosticsOver heating Boiler & overheat limit off .Boiler is blocked with lime
repairReplaced existing Boiler Assembly
locationLos Angeles
Date: 02/13/2019
problemnot cold
diagnosticsEvaporator coils is damege ,leaking freon
repairRepair Existing evaporator coils ,filter dryer,charge freon
locationSanta Monica
Date: 02/12/2019
problemNoisy
diagnosticsCondenser fan motor make loud noisy,fan blade is com off and destroy fan motor shaft
repairReplaced existing condenser fan motor & blade
locationSan bernardino
Date: 12/15/2018
problemnot keeping cold
diagnosticsAfter diagnoses ,found compressor overload relay is burned out
repairReplaced overload relay ,preformed condenser service
locationSan bernardino
Date: 12/15/2018
problemCommercial Grill Vulcan repair
diagnosticsSafety valve not Wrking
repairReplace Safety Valve
locationLos Angeles
Date: 12/12/2018
problemOven does not work ,no heat
diagnosticsAfter diagnoses found electronic ignition module out of order ,burner wont light
repairReplaced ignition module , service and cleaning burner flame sensor and spark electrod
locationLos Angeles
Date: 09/18/2018
problemLeaking water from drain line
diagnosticsDrain heater and insulation is broken, and ice destroy drain line.
repairRemove old insulation and drain heater ,repaid drain line, install new drain heater and insulation .
locationCalabasas
Date: 08/11/2018
problemPilot wont stay on
diagnosticsAfter diagnoses found :safety valve does not work
repairReplaced safety valve .clean and service pilot and burner
locationLos angeles
Date: 07/22/2018
problemNot freezing properly
diagnosticsAfter inspection Freezer ,found TXV valve does not work properly
repair Recovery freon ,replaced TXV valve,preform pressure test ,vacuum seal system ,charge 404 a freon
locationWoodland hills
Date: 07/09/2018
problemNot blowing cold Air
diagnosticsA/C condensing unit 60 amps fuses burned out , compressor power wiring burned out
repairReplaced existing compressor ,charge freon ,Unit working OK.
locationWoodland Hills
Date: 06/28/2018
problemRefrigerator not Cold
diagnosticsCondenser is blocked by dust and grease , low pressure freon ,compressor overheated ,wont start
repairCool off compressor ,replaced overload relay, deep cleaning condenser,charge freon r-134 a
locationBeverly Hills
Date: 06/01/2018
problemnot cold
diagnosticslow pressure freon
repairfond and repair leaking freon on receiver service valve, charge 404 a freon
locationLos Angeles
Date: 04/27/2018
problemIce machine does not make ice
diagnosticsCondenser is blocked, evaporator coils need service
repairDeep cleaning a condenser and evaporator coils water distributing system
locationRedondo Beach
Date: 04/26/2018
problemwine cooler is not cold
diagnosticslow pressure refrigerant condenser is dirty
repairRepair a leak of a refrigerant on a cork valve, charge a refrigerant
locationLaguna Beach
Date: 04/21/2018
problemLeaking Water in side freezer
diagnosticsDrain heater does not work, drain line is frozen
repairreplaced a drain heater, defrost a drain line
locationAgoura Hills
Date: 04/17/2018
problemConvection oven has no heat
diagnosticstemperature control board sensor does not work
repairReplaced temperature control board, temperature sensor
locationEncino
Date: 04/04/2018
problemLeaking water under the unit
diagnosticsDrain line is blocked
repairServicing a drain line, condenser deep cleaning
locationBurbank
Date: 03/23/2018
problemConvection fan motor make noisy
diagnosticsConvection fan motor bearings is broken
repairReplaced fan motor
locationMalibu
Date: 03/21/2018
problemAlto-shaam Oven no heat
diagnosticsHi limit control open Oven over heating
repairReset hi limit control service air vent system
locationPasadena
Date: 03/15/2018
problemIce Machine leaking water
diagnosticsIce machine drain line is broken
repairReplaced drain line
locationOrange
Date: 03/09/2018
problemRefrigerator not cold
diagnosticsRefrigerator condenser fan motor does not work
repairReplaced condenser fan motor and service condenser
locationGardena
Date: 03/09/2018
problemNot working. Won't turn on.
diagnosticsBin control does not work, condenser is dirty , low pressure Freon.
repairReplaced Bin control, preformed condenser service with condenser fan removal, added refrigerant R-404 A
locationNorthridge
Date: 03/07/2018
problemOven won't heat.
diagnosticsAfter through inspection found problem with motor start capacitor.
repairReplaced motor start capacitor, cleaned spark ignition system, oven works okay.
locationOrange
Date: 02/19/2018
problemOven pilot does not stay on.
diagnosticsSafety valve thermocouple does not work.
repairReplaced thermocouple
locationVenice
Date: 02/15/2018
problemIce machine does not make ice.
diagnosticsIce machine evaporator coils are broken.
repairIn progress .
locationVan Nuys
Date: 02/09/2018
problemWalk-in freezer door hinges and door are broken.
diagnosticsWalk-in freezer door need replacement.
repairThe new door for walk-in freezer has been ordered. The door will be installed during the next visit.
locationGardena
Date: 02/09/2018
problemRefrigerator does not work
diagnosticsCompressor does not work
repairReplaced compressor, preform pressure test, charge refrigerant.
locationVan Nuys
Date: 02/08/2018
problemDoes not make cold
diagnosticsSeal system does not work
repairRepair a refrigerant leak on a filter dryer, charge refrigerant A-134.
locationLos Angeles
Date: 02/07/2018
problemOven lights do not work
diagnosticsCommercial oven light switch is not working
repairCommercial oven replaced light switch
locationBeverly Hills
Date: 02/02/2018
problemEvaporator build up Ice and does not make ice
diagnosticsEvaporator Is broken
repairNeed to replace evaporator assembly
locationWoodland Hills
Date: 02/01/2018
problemRefrigerator does not work
diagnosticsCondenser is dirty, does not cool off refrigerant
repairCondenser cleaning and service
locationLong Beach
Date: 01/30/2018
problemleft oven does not work
diagnosticsOven thermostat does not work
repairReplaced oven thermostat
locationLos Angeles
Date: 01/30/2018
problemIce machine does not make ice
diagnosticsGear motor is broken
repairin progress
locationCompton
Date: 01/25/2018
problemWater is leaking inside the refrigerator
diagnosticsDrain line is blocked
repairService drain line tubing, check condenser
locationLong Beach
Date: 01/25/2018
problemIce machine is not making ice, service light is flashing
diagnosticsCirculation water pump hose and water distributor is blocked with mold
repairService and cleaning of the circulation water pump hose, evaporator coils, replaced water filter
locationLong Beach
Date: 01/24/2018
problemAir conditioner is not blowing cold air
diagnostics40 amps fuse burned out
repairreplaced 40 amps fuse, checked refrigerant ,air filter
locationPasadena
Date: 01/24/2018
problemAir conditioner repair, not blowing an air from vent
diagnosticsDuct vent is loose
repairRepair broken duct, checked refrigerant, air filter
locationPasadena
Date: 01/19/2018
problemCommercial oven repair ,under heat
diagnosticsCommercial oven repair ,thermostat not working properly
repairCommercial oven repair ,calibration thermostat
locationLong Beach
Date: 01/19/2018
problemCommercial stove repair, oven does not heat
diagnosticsCommercial stove repair, oven thermostat is broken
repairCommercial oven repair,replaced oven thermostat
locationLong Beach
Date: 01/19/2018
problemCommercial ice machine does not make ice
diagnosticsPower switch is broken
repairReplaced power switch
locationArtesia
Date: 01/17/2018
problemCommercial Display Case is leaking
diagnosticsDiscovered a leak in a drain line
repairReplaced a drain line, same day repair.
locationLos Angeles
Date: 01/16/2018
problemCommercial ice machine does not make ice
diagnosticsFlow valve is broken
repairReplaced flow valve
locationPasadena
Date: 01/05/2018
problemWalk in refrigerator is not making cold
diagnosticsAfter inspection Walk in fridge: found low pressure as the result of a refrigerant R-404a leak
repairRepair leak, recharge refrigerant R-404a
locationSan Bernardino
Date: 12/20/2017
problemCommercial Refrigerator repair not cold
diagnosticsTemperature control is not working, ice build up in evaporator coils
repairDeice evaporator coils, replace temperature control
locationLos Angeles
Date: 12/13/2017
problemCommercial stove repair ,right oven no heat
diagnosticsConvection fan motor ,start capacitor is not working
repairCommercial stove repair,Replace motor start capacitor
locationLos Angeles
Date: 11/27/2017
problemCommercial Oven repair, does not heat
diagnosticsCommercial Convection oven repair,Spark module is broken
repairCommercial double oven repair,replaced spark module. Customer was satisfied with the speed and quality of the repair.
locationPanorama City
Date: 11/20/2017
problemCool table is not cold
repairTechnician found a compressor failure. Replace a compressor, perform a pressure test for freon leaks, using ultra fluorescent additive on distributor valve, recharge freon.
locationLos Angeles
Date: 11/17/2017
problemIce machine does not produce ice. No ice.
diagnosticsCommercial ice machine clog with calcium deposit
repairPeform a sanitation and cleaning of a calcium deposit, repair dump valve, condenser service ,and fix ice machine
locationEncino
Date: 11/17/2017
problemIce machine is not producing ice
repairharvest switch was blocked, performed a sanitation, repair a harvest switch, provided maintenance, checked a freon levels.
locationLong Beach
Date: 11/13/2017
problemchecked refrigerator and found freon leak in a sealed system
repairtechnician repaired leak in evaporator coils, changed freon and performed condenser service
locationReseda
Date: 08/30/2017
problemCommercial refrigerator, not cold
diagnosticsCommercial refrigerator,low level of refrigerant
repairTechnician found a freon leak using ultra fluorescent additive on distributor valve. Repaired a leak, recharge freon.
locationLos Angeles
Date: 08/06/02021
problemCommercial Norlake Refrigerator is not cold enough, too warm.
diagnosticsInspected the Norlake Refrigerator and found: Refrigerant level is low due to a leak.
repairRecommended to repair the refrigerant leak and charge refrigerant.
locationWoodland Hills
© Copyright 2017-18 LA Appliances Time